Mitsubishi QD75M1 User Manual page 427

Qd75m series. positioning module.
Hide thumbs Also See for QD75M1:
Table of Contents

Advertisement

9 MAJOR POSITIONING CONTROL
In speed control
Speed
Current feed value during speed control start is maintained
(a) Current feed value not updated
Current feed value during 3-axis speed control
The following table shows the "
control corresponding to the "
settings. (Note that the reference axis setting values are used for parameters.)
Pr.21 Current feed value during speed
control" setting
0: Do not update current feed value
1: Update current feed value
2: Zero clear current feed value
Speed
t
Current feed value is updated
(b) Current feed value updated
Restrictions
(1) Set "termination" in "
control not possible (error code: 516)" will occur and the operation cannot start
if "continuous positioning control" or "continuous path control" is set.
("Continuous positioning control" and "continuous path control" cannot be set
in speed control.)
(2) Set the WITH mode in "
an M code. The M code will not be output, and the M code ON signal will not
turn ON if the AFTER mode is set.
(3) Set the "reference axis speed" in "
method". An "Interpolation mode error (error code: 523)" will occur and the
operation cannot start if a composite speed is set.
Md.20
Current feed value" during 3-axis speed
Pr.21
current feed value during speed control"
The current feed value at speed control start
is maintained.
The current feed value is updated.
The current feed value is fixed at 0.
In speed control
t
Da.1
Operation pattern". An axis error "Continuous path
Pr.18
M code ON signal output timing" when using
Pr.20
Interpolation speed designation
9 - 74
MELSEC-Q
Md.20 Current feed value
In speed control
Speed
0
(c) Current feed value zero cleared
t

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75m2Qd75m4

Table of Contents