Mitsubishi QD75M1 User Manual page 413

Qd75m series. positioning module.
Hide thumbs Also See for QD75M1:
Table of Contents

Advertisement

9 MAJOR POSITIONING CONTROL
Circular interpolation error compensation
In circular interpolation control with center point designation, the arc path
calculated from the start point address and arc address may deviate from the
position of the end point address set in "
amount".
Pr.41
(Refer to "
Allowable circular interpolation error width".)
(1) Calculated error < "
Circular interpolation control to the set end point address is carried out while
the error compensation is carried out. (This is called "spiral interpolation".)
Path using spiral interpolation
Start point address
In circular interpolation control with center point designation, an angular
velocity is calculated on the assumption that operation is carried out at a
command speed on the arc using the radius calculated from the start point
address and center point address, and the radius is compensated in proportion
to the angular velocity deviated from that at the start point.
Thus, when there is a difference (error) between a radius calculated from the
start point address and center point address (start point radius) and a radius
calculated from the end point address and center point address (end point
radius), the composite speed differs from the command speed as follows.
Start point radius > End point radius: As compared with the speed without
Start point radius < End point radius: As compared with the speed without
(2) Calculated error > "
At the positioning start, a "Large arc error deviation error (error code: 506)" will
occur and the control will not start. The machine will immediately stop if the
error is detected during positioning control.
Da.6
Pr.41
Allowable circular interpolation error width"
Error
Center point address
error, the speed becomes slower as
end point address is reached.
error, the speed becomes faster as
end point address is reached.
Pr.41
Allowable circular interpolation error width"
9 - 60
MELSEC-Q
Positioning address/movement
Calculated end point
address
End point address