5 DATA USED FOR POSITIONING CONTROL
Set with a decimal.
Actual value
Cd.16 Inching movement amount
Setting value
R
(Decimal)
Example: When the " Cd. 16 Inching
movement amount" is set as
"1.0 m", the buffer memory
stores "10".
Set with a decimal.
Actual value
Cd.17 JOG speed
Setting value
R
(Decimal)
Example: When the " Cd. 17 JOG
speed" is set as "20000.00mm
/min", the buffer memory
stores "2000000".
Set with a decimal.
Setting
K
1
value
The QD75 resets the value to "0" automatically when the continuous
control interruption request is processed.
(This indicates the completion of continuous operation interruption request.)
Setting value
Conversion into an integer value
n
10
Conversion into an integer value
n
10
Interruption request continuous operation
1: Interrupts continuous operation control
or continuous path control.
Unit conversion table ( Cd.16 )
n
Unit
m
-1
-5
inch
-5
degree
PLS
0
Unit conversion table ( Cd.17 )
n
Unit
mm/min
-2
inch/min
-3
-3
degree/min
PLS/s
0
5 - 149
MELSEC-Q
Storage buffer
Default
memory address
value
Axis 1 Axis 2 Axis 3 Axis 4
0
1517 1617 1717 1817
1518
1618
1718
0
1519
1619
1719
0
1520 1620 1720 1820
1818
1819