Mitsubishi QD75M1 User Manual page 209

Qd75m series. positioning module.
Hide thumbs Also See for QD75M1:
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.24
Axis warning No.
Md.25
Valid M code
Md.26
Axis operation status
Md.27
Current speed
Whenever an axis warning is reported, a related warning code is stored.
This area stores the latest warning code always. (Whenever an axis warning is
reported, a new warning code replaces the stored warning code.)
Cd.5
When the "
Axis error reset" (axis control data) is set to ON, the axis
warning No. is cleared to "0".
This area stores an M code that is currently active (i.e. set to the positioning data
relating to the current operation).
Update timing
: turning ON of the M code ON signal
When the PLC READY signal (Y0) goes OFF, the value is set to "0".
This area stores the axis operation status.
This area stores the latest value of the command speed. (Stores "0" under the
speed control.)
Da.8
If "
Command speed" is set to "-1", this area stores the command speed
set by the positioning data used one step earlier.
Da.8
If "
Command speed" is set to a value other than "-1", this area stores the
command speed set by the current positioning data.
5 - 122
Storage details
MELSEC-Q

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd75m2Qd75m4

Table of Contents