8.6.20 Relay Options explained

Function
Fence x
Fence x
alarm or off
Fence
Bipolar
Armed x
General
Siren
Strobe
AC Fail
Battery
Tamper
Group
wide x

8.6.21 Group Mode (26x#)

A group must have only one master. The other units in
the group are slaves. Group Voltage display units require
each slave to have a different number. Since the keypad
bus is common among the group one keypad can be used
to program all units for all options except this one.
The procedure is:
Connect the keypad to each unit in turn, before linking all
units into a group. Set this option: one unit as master the
other as slaves.
NOTE: In some markets group mode may not be available.
For details on group wiring and operation see below.
1. Make sure the key switch is turned off and Input1
is not connected to the Com terminal.
2. Connect the battery.
3. Connect the keypad.
4. On the keypad, enter [Installer's code] [*] [0] [#], then [26].
5. Enter the required value (e.g. [1] for master) then [#].
6. Enter [*] [#] to exit programming.
7. Connect the group using the keypad bus as per Figure 7.
NOTE: At this time groups are limited to a master and 14 slaves (15 zones in total).
If more zones are required, the LAN interface boards can be used. (PAE 212)
32
JVA ELECTRIC FENCE SYSTEMS
Logic for alarm state (opposite of normal state)
Fence x Alarm: Zone x is Armed (Pulsing) AND the Fence Return Voltage has
fallen below the Fence Alarm Voltage for more pulses than the Missed Pulse
Count. Not latched.
Zone x is Off OR the Fence Return Voltage has fallen below the Fence Alarm
Voltage for more pulses than the Missed Pulse Count. Not Latched.
Energizer is Armed (Pulsing) AND the Fence Return Voltages on either Bi-
polar return line has fallen below the Fence Alarm Voltage for more pulses than
the Missed Pulse Count. Not latched.
Zone x is Armed (Pulsing)
AC Fail OR Tamper OR Low Battery OR Gate Alarm OR Internal Error. Latched
for internal errors only.
Fence Alarm 1 OR Fence Alarm 2 OR Gate Or Tamper, will time out after the
Siren Time Out time. This function is latched.
As per Siren but does not time out, will remain On until both Zones are
switched off. This function is latched.
Alarm on AC Fail
Alarm on low or bad battery
Alarm when the lid is up and J3 is not fitted
Group relay functions are the collected status of the whole group of Z energiz-
ers. Group Armed for example is set only if all energizers in the group are armed.
Value (x)
Mode
0
No Group
1
Master
2
Slave 1
3
Slave 2
4
Slave 3
5
Slave 4
6
Slave 5
7
Slave 6
etc
etc
15
Slave 14
Group Mode (26x#)