6.7 Standby Battery

Should there be a loss of mains power, the Power Light on the keypad will go off.
The unit will switch to a reduced output to conserve battery power. If the loss of
power is prolonged, the battery may discharge power and become ineffective. The
Power Light will start to flash indicating a battery low power problem. If the battery
is depleted, the unit will not pulse.
If the standby battery requires replacement, the Power Light will flash and the
Status Light will be flashing three times.

6.8 Status Light

The energizer status light indicates that the energizer requires attention. See
section 7.2, page 22.

6.9 Keypad Control in Brief

In the following table, XXXX is the 4-digit USER PIN. The default USER PIN is
1 2 3 4.
ACTION
Turn on / ARM
Turn off / DISARM
Silence an alarm
Switch to Low Power mode (all zones)
Switch to High Power mode (all zones)
Arm All Zones (Multizone systems)
Arm Zone 1 or Master
Arm Zone 2 (2 Zone models only) or Slave
1 etc.
Disarm All Zones
Disarm Zone 1 or Master
Disarm Zone 2
6.10 Solar Powering the Unit
If there is no mains power on the site, the Z14 can be powered as follows: A 105
Amp/hour battery charged by a 75 watt solar panel. This is a guideline. A bigger
panel may be required in some cases. If operating from an externally charged
battery, fit Jumper J3, to inhibit mains fail alarm.