JVA ELECTRIC FENCE SYSTEMS

8.6.7 Siren On Time (08x#)

This option sets the duration of time that
the siren will remain on after a fence alarm
occurs. After this time the siren will turn off
for the Off time indicated in Table 8.6.8.
The siren will sound again if the alarm is
still present after this Off time has passed.
The default is 3 minutes.
This may be the subject of local
regulations to stop an alarm causing
undue disturbance to neighbours, etc.
NOTE: The siren On time will be cut short
if the battery falls below the low battery
level.
Firmware version 7.95 changes options:
Value
0
1
2
3
4
5
6
7
8
9

Siren Off time (09x#)

8.6.9 Siren Cycles (10x#)

This option sets the maximum number of
times the siren will sound for the On time if
the alarm continues. This may be limited by
local regulations to stop an alarm causing
undue disturbance to neighbours, etc.
NOTE: This is the maximum number of
cycles for 1 continuous alarm, intermittent
alarm events could cause more than this
number of siren soundings.
Time
10 Seconds
1 Minute
2 Minute
5 Minutes
10 Minutes
20 Minutes
30 Minutes
40 Minutes
50 Minutes
60 Minutes
Value
0
1
2
3
4
5
6
7
8
9
Siren On time (08x#)
Value
7
8
9
7.95 firmware
8.6.8 Siren Off time (09x#)
This option sets the amount of time
the siren will be off for after the on time
above has expired. If an alarm is still
present after this Off time, the siren will
sound again.
Value
0
1
2
3
4
5
6
7
8
9
Siren Cycles (10x#)
Time
10 Seconds
30 Seconds
1 Minute
2 Minutes
3 Minutes
4 Minutes
5 Minutes
6 Minutes
7 Minutes
8 Minutes
Time
20 Minutes
45 Minutes
130 Minutes
Cycles
0
1
2
3
4
5
6
7
8
9
27