Installation Steps - Group Mode - JVA Z14 Installation And User Manual

Security
Hide thumbs Also See for Z14:
Table of Contents

Advertisement

5.4 Installation Steps – Group Mode
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
NOTE:
1.
Members of a group can be individually switched on and off; even the master
can be turned off via input or key switch.
2.
A slave will generate a General alarm if the keypad bus is broken between it and
the group master.
3.
After programming the Keypad may be disconnected, it is not required for group
operation.
4.
As of energizer firmware 7v83 and keypad firmware 1v09, Z28's should have
an 'empty' ID between each Energizer. This means if the Z28 master ID=1, then
the ID of the first slave should be 3, not 2.
5.
When connected to Perimeter Patrol, the arm/disarm function of a keypad is
disabled. Control of these functions is through the Perimeter Patrol interface.
6.
A Keypad that is connected to a Slave Energizer (that is disconnected from the
Group) must have a KEYPAD ADDRESS set to 1 or 8. Otherwise the Energizer
will not respond to commands.
16
JVA ELECTRIC FENCE SYSTEMS
Disarm all energizers in the group. If energizers are not disarmed Step
10 may not work correctly.
Program the keypad address using one of the energizers.
Program each energizer with its required address (Master address = 1,
Slave 1 address = 2...). Refer to note 4 below.
Connect any control/monitoring unit 12V, GND and Data to the Group
Master
Connect all the slaves Data and GND to the Group Master.
Connect the battery and AC power of the Group Master but do not arm.
Connect the battery and AC power of each slave Note: Do not arm them
until all the Energizers in the group are connected
Wait 5 minutes for all the Energizers to synchronise with the Master
If there are more than one keypad or control unit, make sure they have
a different ID then reset the group using keypad code: [user pin] [*] [6]
[8] [#] or Perimeter Patrol "Reset All" this will allow both keypads to be
recognised by all energizers in the group.
Enter the key sequence [*][6][8][#] to automatically re-scan the group
and check what energizers are connected.
Arm the group using keypad [1] [2] [3] [4] [*] [1] [0] [#] or Perimeter Patrol,
make sure all Energizers are activated.