Fence Mode(15X#); Binary Options (16X#); Anti-Bridging Threshold (17X#) - JVA Z14 Installation And User Manual

Security
Hide thumbs Also See for Z14:
Table of Contents

Advertisement

JVA ELECTRIC FENCE SYSTEMS
8.6.14 Fence Mode (15x#)
This option sets Bi-Polar or Conventional
modes.
NOTE: Changing modes requires hard-ware
reconfiguration by a JVA technician. This
service is available from any JVA Electric
Fence and Security Centre (0861 782 349).
Value
0
None
+1
None
+2
Max Power
+4
2.5 Joules Limit
+8
IR Tamper enabled
+16
Stop slave on coms fail
+32
Do not send Alarm
memory

Binary Options (16x#)

7.84. Also limits a Z14 to 2.5J per zone in group mode. Added 7.86.
+8: Enables the IR tamper detection under the lid. J3 changes function to inhibit
tamper.
+16: Stop slaves on E-16 if the communications from the group master is lost.
+32: Stops the energizer sending Alarm Memory to a PC, relay PCB or keypad. Set
this to restore Unlatched mode on a PAE201 relay PCB.
NOTE: +8 and +16 added in code version 7.86. +4 to +16 all default to On (strict IEC
compliance) for a Z14R (i.e. if option 15 = 2 or 3). +32 added in code version 7.87.

8.6.16 Anti-bridging threshold (17x#)

Anti-bridging has been designed to detect a section of fence being bypassed, and
removed from circuit, by an intruder bridging the feed to returns together and then
cutting the live wires. Setting this option to a value greater than 0 (default is 0 = off) will
enable Anti-bridging, however this feature will not operate in low power mode! While
Armed, a Fence Alarm will trigger if the Fence Voltage rises OR falls quickly by more
than the threshold. A slow change to the voltage will not trigger a Fence Alarm until the
Voltage is less than the Fence Alarm Voltage (03x#)
Time
Value
0
1

Fence Mode(15x#)

8.6.15 Binary Options (16x#)
Each option in this table can be turned
on by adding the corresponding value.
For option + 1 set 16 to 01, for + 1 and
+2 set 16 to 03.
+2: Maximum power at all times. Note
turning this option on may remove IEC
standards compliance. Added in code
version 7.80.
+4: Limits outputs to 2.5 Joules per
Zone on a Z28. Added in code version
Function
Bi-Polar
Conventional
29