Programming Options In Brief - JVA Z14 Installation And User Manual

Security
Hide thumbs Also See for Z14:
Table of Contents

Advertisement

See page 23 for more detail.
Option
01
02
03
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
24
JVA ELECTRIC FENCE SYSTEMS
Function
Description
Power Level
Sets the output power levels
Low Power level
Sets the output power levels used in Low Power mode
Fence Alarm
Sets the voltage threshold below which the fence alarm will
Voltage
occur
Low Power
Sets the voltage threshold below which the fence alarm will
Alarm Level
occur in Low Power mode
Missed Pulse
Sets the number of pulses which may be missed before the
Count
alarm is activated
Battery Alarm
Sets the battery voltage threshold below which the general
Voltage
alarm will activate
Siren On Time
Sets the time that the siren (and keypad beeper) will stay on
after an alarm
Siren Off Time
The amount of time the siren will be off for after the On time
has expired
Siren Cycles
The number of times the siren will sound for the On
time function above. After this many cycles the siren will
automatically mute
Input Inversion
Input normally open or normally closed
Gate Input
Gate Switch mode or Low Power Switch mode
Function
Gate Exit Delay
Time from gate switch opening to alarm
Chime Mode
Allows the keypad and internal beeper function to be altered
Fence Mode
Bi-Polar or Conventional mode. Requires hardware change,
which can be done by nearest JZA service centre
Binary Options
Miscellaneous options
Anti-bridging
If the voltage rises OR falls quickly by more than this setting
as a percentage of the average fence voltage the alarm will
occur
Binary Options 2
Miscellaneous options
Not used
Auto Re-arm
Sets the time which must elapse after an alarm has timed
Time
out (completed the Siren Cycles) before the Energizer will
automatically re-arm ready for the next alarm event.
Relay 1
Used to assign an alarm function to relay 1
Relay 2
Used to assign an alarm function to relay 2
Relay 3
Used to assign an alarm function to relay 3
Relay 4
Used to assign an alarm function to relay 4
Relay 5
Used to assign an alarm function to relay 5
Group Mode
Allows the energizer to be set as a Master or slave in a
synchronized group. Not available in all markets.
Programming Options