JVA ELECTRIC FENCE SYSTEMS
8. INSTALLATION PROGRAMMING OPTIONS
The Z14 has a non-volatile memory in which are held programming options (setup
parameters). These are factory pre-set but can be field programmed using a keypad.
8.1 Programming Mode
To enter Programming mode, enter the 6-digit INSTALLER PIN followed by *0#
keys. The keypad will beep twice to indicate that the command was accepted. If the
INSTALLER PIN was incorrect, the keypad will beep 3 times. The LCD will now show
the first programming option and its current setting.
Pressing the # key will cycle through all the options on the LCD.
NOTE: Not all numbers are used. The default INSTALLER PIN is 0 1 2 3 4 5.
8.2 To Exit Programming Mode
After programming, press *# to exit. If left unattended, the unit will time out and auto
exit Programming mode after approximately 5 minutes.
8.3 Changing the Installer PIN
The INSTALLER PIN may only be changed while in Programming mode.
To enter a new INSTALLER PIN, press 00 followed by the new 6-digit PIN, then the
# key.
If you cannot remember your INSTALLER or USER PIN, return the unit's memory
to default. To do this, remove power (AC off and disconnect the battery), open the
energizer, remove jumper J4 and reconnect the battery for about 10 seconds. Re-fit
J4. This will return all options to the factory set defaults.
8.4 Changing an Option
Most of the options have possible values in the range of 0 to 9.
To change any options, the unit must be in Programming mode. Check the option
number (see table below) and then the table of values for that option. Then press the
option number followed by the required value. When the programming is completed,
exit from Programming mode. (See above.)
For example, to change the power level to maximum, press 019#, and the keypad will
beep twice to indicate that the command was successful. The LCD will immediately
show the updated value.
8.5 Programming Options in Brief
23