Z28 U
M
ser
anUal
J VA T E CH N O LO G I E S
www.jva-fence.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Z28 and is the answer not in the manual?

Questions and answers

Summary of Contents for JVA Z28

  • Page 1 Z28 U anUal J VA T E CH N O LO G I E S www.jva-fence.com...
  • Page 2 Key8 Key9 Enter Programming Mode Installer Pin When you have entered Programming mode you can begin to enter the following options to configure your Z28 Se- curity Energizer. Default Values are highlighted in grey. Command Key1 Key2 Keys 3 and 4...
  • Page 3 Command Key1 Key2 Keys 3 and 4 Key5 Return 1 Fence Enter the value in Hundreds of Volts Alarm Voltage For Example: to set 3.8kV, use 38 for keys 3 and 4. Default is 40 (4.0kV) High Power Mode Return 2 Fence Enter the value in Hundreds of Volts Alarm Voltage For Example: to set 3.8kV, use 38 for keys 3 and 4.
  • Page 4 Quick Start Guide Command Key1 Key2 Keys 3 and 4 Key5 Siren Off Time 10M 20M 30M 40M 50M (S=Seconds, M=Minutes) Siren Cycles Gate Entry/Exit Delay (S=Seconds, M=Minutes) Chime Mode None Door Chime Siren Fence Gate Beeps Alarm Plus Siren +128 Combined Options 1 (Add...
  • Page 5 Command Key1 Key2 Keys 3 and 4 Key5 Combined Options 2 +128 (Like Combined Siren Enable 4800 9600 Chirp on Entry Baud Baud Options 1) Exit Gate Auto Re-arm Time S=Seconds, Min, D=Disabled Relay 1 Explained under “1.1.1 Relay Functions” Default is 09 (Strobe 1) Relay 2 Explained under “1.1.1 Relay Functions”...
  • Page 6 Quick Start Guide 1.1.1 Relay Functions The table below is for use for the relay programming options mentioned in the table on the previous page. Keys 3 Function Description and 4 Fence 1 Triggers when Zone 1 is Armed and Return Voltage is below the Threshold Voltage Fence 1 or Off Triggers when Zone 1 is Disarmed or Return Voltage is below the Threshold Voltage Armed 1...
  • Page 7 Keys 3 Function Description and 4 Siren Caused by Behaves like siren, only for Gate Alarms Gate Armed - Low Triggers when Armed in Low Power mode Power Mode Group Armed Triggers when group is Armed. Only configurable on group master. Group general Triggers on group general Alarm.
  • Page 8: Input Functions

    Quick Start Guide 1.1.2 Input Functions Key3 Input Trigger Key4 Input Function Normally Open (Active when Closed) Arm All Zones when Active / Disarm otherwise Normally Closed (Active when Open) Arm Zone 1 when Active / Disarm otherwise Momentary Toggle (Toggle between states) Arm Zone 2 when Active / Disarm otherwise NO Pulse Extend (Extend a short Close signal by 3 Low Power when Active / High Power otherwise.
  • Page 9 SUMMARY OF KEYPAD FUNCTIONS Command Key1 Key2 Key3 Key4 Key5 Key6 Key7 Key8 Key9 Key10 Arm/Disarm USER PIN Silence the Energizer Siren Enter Programming Mode INSTALLER PIN Enter Keypad Programming Mode INSTALLER PIN Exit Programming (Any Mode) Change a User PIN, 4 Digits USER PIN [New PIN]...
  • Page 10 Quick Start Guide Command Key1 Key2 Key3 Key4 Key5 Key6 Key7 Key8 Key9 Key10 Re-enable Siren USER PIN Re-enable Specific Zone Siren USER PIN Zone Number Bypass Gate Alarm (All Zones) USER PIN Bypass Specific Gate Alarm USER PIN Zone Number Re-enable Gate Alarm (All Zones) USER PIN Re-enable Specific Gate Alarm...
  • Page 11 (Trigger the Siren and Disarm the Energizer) Keypad Specific Function Key1 Key2 Key3 Key4 Re-analyse the Energizer Group Keypress Beep On/Off Chimes On/Off Error Tones On/Off Keypad Alarm Tones On/Off Change Backlight Mode Display Keypad Model JVA Z28 Manual Page 15...
  • Page 12 Z-Series energizer, or the configuration of the unit itself. To test your unit it is best to connect your Z28 with a test fence, this is done by connecting the cables as shown in the picture below.
  • Page 13 Power the Z28 and then Arm it. The unit should begin pulsing and not show any alarms. Disarm the Z28 and remove the fence cable as shown in the picture below. Arm the Z28 once again, after 3 pulses (unless you configured it otherwise) the unit should go into alarm as the fence will appear to be cut.
  • Page 14 CONNECTING YOUR Z28 TO THE FENCE This is covered under “5.3 Example of Fence Wiring” on page 32. In depth installation instructions begin on page 30. After the Z28 has been wired up you can begin to protect your perimeter.
  • Page 15 MOST FREQUENTLY USED LCD KEYPAD COMMANDS For a full list of all keypad commands please see “10.6 Summary Of Keypad Functions” on page 60. Default Installer PIN 012345 Default User PIN 1234 First you need to connect the Z-Series LCD keypad to the Z-Series device. Once you have a keypad connected you can refer to the table below to control the Z-Series device.