JVA ELECTRIC FENCE SYSTEMS

8.6 Programming Options in detail

8.6.1 Power Level (01x#)

The power level option allows the shocking
power of the fence to be adjusted. For
example: To change the power level to
maximum, enter the following:
0 1 9 # or 0 1 0 9 #.
The keypad will beep twice to indicate that
the new setting has been accepted.
The normal fence voltage depends on the
amount of fence wire, the losses and the
power level.
This setting affects the average power
drain and therefore backup battery time.
Kilovolt settings refer to a 1000 Ohm load,
actual fence voltages will depend on the
type and length of fence.
Value (x)
% of High Power
0
1
2
3
4
5
6
7
8
9

Low Power Level (02x#)

8.6.3 Fence Alarm Voltage (03x#)

This option sets the voltage threshold
below which the fence alarm will occur.
The default Fence Alarm Voltage is 4 kV.
In Bi-Polar mode this threshold is for both
positive and negative fence wires.
Note: The bold panel in each table indicates
Value (x)
8.6.2 Low Power Level (02x#)
Same as above, but for Low Power mode.
0.5%
1.0%
1.5%
Value (x)
2.0%
2.5%
3.0%
3.5%
4.0%
4.5%
5.0%
the default value.
Voltage
Conventional
Mode
0
± 5.0kV
1
± 5.5kV
2
± 6.0kV
3
± 6.5kV
4
± 7.0kV
5
± 7.5kV
6
± 8.0kV
7
± 8.5kV
8
± 9.0kV
9
± 9.5kV
Power Level (01x#)
Voltage
Conventional
Mode
0
1.5kV
1
2.0kV
2
2.5kV
3
3.0kV
4
3.5kV
5
4.0kV
6
4.5kV
7
5.0kV
8
5.5kV
9
6.0kV
Fence Alarm Voltage (03x#)
Voltage
Bi-Polar
Mode
2.5kV
2.8kV
3.0kV
3.3kV
3.5kV
3.8kV
4.0kV
4.3kV
4.5kV
4.5kV
Voltage
Bi-Polar
Mode
1.5kV
1.8kV
2.1kV
2.4kV
2.7kV
3.0kV
3.3kV
3.6kV
3.9kV
4.2kV