Input Inversion (11X#); Gate Input Function (12X#); Gate Entry/Exit Delay (13X#); Chime/Self-Resetting Mode (14X#) - JVA Z14 Installation And User Manual

Security
Hide thumbs Also See for Z14:
Table of Contents

Advertisement

8.6.10 Input Inversion (11x#)

The control inputs can be inverted,
unless an input is used for a Gate switch,
in which case it is always NC.
8.6.11 Gate Input Function/Low
Power mode (12x#)
This option is used to set the mode for
the gate input. If set to 0, the gate alarm
will trigger if the gate is opened. If set to
1, the unit will go into low power if the
gate input is closed.
Value
0
1
2
3
4
5
6
7
8
9

Gate Entry/Exit Delay (13x#)

Value
0
1
2
3
4
28
JVA ELECTRIC FENCE SYSTEMS
Time
0 Seconds (Immediate)
30 Seconds
1 Minute
2 Minutes
3 Minutes
4 Minutes
5 Minutes
6 Minutes
7 Minutes
8 Minutes
Function
None
Door Chime
Siren
Fence Alarm
Gate beeps
plus Siren
Chime Mode (14x#)
Value
0
1
2
Input Inversion (11x#)
Value
0
1

Gate Input Function (12x#)

8.6.12 Gate Entry/Exit Delay (13x#)
The gate switch must remain open for longer
than the Gate Entry/Exit Delay before the
Gate Alarm is triggered. If the switch closes
within this time, the Gate timer is reset to
the Gate Entry/Exit Delay value.
8.6.13 Chime Mode (14x#)
This option allows the Energizer's
internal, and keypad, beeper to be used
as a door chime for the gate switch.
When set to None, the keypad beeper
is used to indicate correct keypad
operation only. When set to Door Chime,
the beepers will sound when the gate
switch opens, even if the energizer is
disarmed. Note "Gate" must be selected
in Input 2 Function (Option 12).
If set to Siren, the beepers mimic the
siren function.
Gate Beeps plus Siren will give 2 beeps
on Gate open and 4 on close, plus
continuous for an alarm. Beeps are on
Keypad only, not internal beeper.
NOTE:
Gate must be selected in option 12.
Function
Normally open
Normally closed
Momentary Input
Function
Gate
Low Power

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents