6. OPERATION

6.1 Control

Your JVA Z14 security energizer has been designed for ease of operation.
Key Switch: In its simplest form, the energizer is controlled by the key switch on
the side of the unit.
Keypad: The optional keypad allows the user to have completely secure control
of the energizer on a neat, small keypad at a location up to 100 metres from the
energizer, such as a bedroom, without having to have the large energizer box and
ticking noise in the room. The energizer can be installed in a garage or location
close to the fence, while the keypad can be positioned in an easily accessible place.
The specific system's information, e.g. mains power, energizer on/off, fence alarm,
auxiliary alarm, etc., are displayed on the keypad.
If a keypad is connected, the key switch and control input terminal may not be
operational as they may have been disconnected by the installer.
If both the key switch and keypad are connected to the energizer, then the last
change will determine the result. For example, if the unit is armed via the keypad and
then disarmed using the local key switch, it will disarm.
If in doubt consult your installer.

6.2 Arming the Fence Using the Keypad

Enter your PIN number (four digits long) and push the # key. (Default is 1 2 3 4)
Make sure the red ARM light comes on.
The keypad will beep twice to confirm that the system is armed.
The fence will power up and if all is well (no faults) the system will be ready to
deter and detect.
If there is a fault on the fence and it cannot achieve full voltage, the LCD screen
will indicate that there is a fault.
To disarm the system, enter your PIN and press #. This will also clear any fault
lights and zone lights which may have been on.

6.3 Turning to Low Power mode

To switch to Low Power mode, enter your PIN and press *41#. In Low Power mode
the fence will still be powered and any breach will be detected, but the voltage will
be much lower than normal operation. The ARM light will flash in Low Power mode.
Enter your PIN and press *42# to switch back to Full Power mode.
Alternatively, the unit can be switched to Low Power mode using the gate switch
input, if it has been programmed accordingly. See Programming Options, page 23.