JVA ELECTRIC FENCE SYSTEMS

6.4 When an Alarm Occurs

If the system is armed and the fence is tampered with, the Fence Light will flash and
then remain on. A siren or strobe connected to the unit will turn on. If the energizer
is connected to an alarm system for monitoring, an alarm signal will be sent to the
alarm company monitoring the alarm system.
An alarm will also sound if the gate input is opened and the entry/exit delay time has
elapsed.
After the siren has cycled on and off according to the times and numbers set in
options, the siren will stop sounding. The on and off timing is able to be set in the
options. The Strobe will remain on. After a further delay (Auto Rearm Time) the siren
will again respond to the next alarm condition with a new set of on / off cycles.
If the alarm condition (low fence voltage or gate input) is removed, the siren will stop
after the end of the current "on" time (Siren On Time).
If the siren is muted by (entering PIN#) then the siren will enter the next "off" cycle
(Siren Off Time). If the alarm condition is still present (voltage is low) the siren will
sound again after the preset "off" time. If the alarm condition is not present the
Energizer is instantly rearmed, irrespective of the auto-rearm setting.

6.5 To Silence the Alarm

Enter your PIN and press #. This will silence the alarm but not disarm the system;
the Armed Light will still be on. The system will be ready for the next alarm.
Note that the following functions have an effect on alarm timing: Siren On time,
Siren Off time, Siren Cycles, Auto Re-arm time).
The siren and strobe are ready to respond again if triggered.
To disarm the system, enter your PIN and press # again. This will also clear the
fence alarm light.
Alternatively, disarming using the key switch will reset the alarm.
If you silence an alarm and the problem is still present when the unit is rearmed,
the siren will sound again after the programmed off time has elapsed.
To clear the alarm memory, press * 1 #

6.6 Changing the PIN Number

Enter the old USER PIN and press *0#. This enters User Programming mode.
Enter the new USER PIN (must be 4 digits) and then #. (Repeat to confirm PIN.)
Press *# to exit User Programming mode.
Make sure the new USER PIN works by using it to arm the energizer.
The default USER PIN is 1 2 3 4.