Configuration Tasks

Shutting Down and Removing the Cisco WebEx Node SPA

Because the Cisco WebEx Node SPA has a hard disk drive (HDD), it is necessary to shut down gracefully
before physically removing the SPA from the Cisco ASR 1000 Series Router. This action allows the
operating system to unmount the file system and put the HDD in standby mode to prevent data corruption
or physical damage to the HDD.
The Cisco WebEx Node SPA can be shut down in one of two ways:
Command
Router# hw-module subslot slot/subslot
stop
Make sure to wait until the SYS LED turns off before removing the SPA.
Caution
The following example shows the use of the hw-module subslot stop command:
Router# hw-module subslot 0/0 stop
ASR1004#
*Feb 18 12:37:32.260: %SPA_OIR-6-OFFLINECARD: SPA (SPA-WMA-K9) offline in subslot 0/0
*Feb 18 12:37:32.260: %ASR1000_OIR-6-SOFT_STOPSPA: SPA(SPA-WMA-K9) stopped in subslot 0/0,
interfaces disabled
ASR1004# show platform
Chassis type: ASR1004
Slot
--------- ------------------- --------------------- -----------------
0
0/0
0/1
R0
F0
P0
P1
Slot
--------- ------------------- ---------------------------------------
0
R0
F0
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Software Configuration Guide
22-8
You can use the hw-module subslot stop command to gracefully shut down the SPA before
physically removing the hardware from the chassis. To shut down the Cisco WebEx Node SPA, use
the following command in EXEC mode:
You can use the Shutdown button located on the left side of the faceplate. Use the tip of a pen or
other similar blunt object to press the button.
Once the shutdown operation is initiated by either method, the SYS LED starts to blink (green) to
indicate the shutdown operation is in progress. Once the shutdown operation is completed, the SYS
LED turns off to show that the SPA can now be removed.
Type
ASR1000-SIP10
SPA-WMA-K9
SPA-WMA-K9
ASR1000-RP1
ASR1000-ESP10
ASR1004-PWR-AC
ASR1004-PWR-AC
CPLD Version
07091401
07062111
07051680
Chapter 22
Configuring the Cisco WebEx Node for ASR 1000 Series
Purpose
Shuts down the Cisco WebEx Node SPA located in the
slot and subslot locations indicated.
State
Insert time (ago)
ok
16:20:50
stopped
00:00:13
ok
16:18:32
ok, active
16:20:50
ok, active
16:20:50
ok
16:19:23
ok
16:19:23
Firmware Version
12.2(33r)XN2
12.2(33r)XN2
12.2(33r)XN2
OL-14127-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents