Skoda Octavia 1996 Service Manual page 106

Table of Contents

Advertisement

20
¡ ¢ £
------------
------------
Fuel Supply System
K -
Slacken the bolted connections -arrows- at
the front left and at the retaining straps.
-
Lower fuel tank.
Installing
Installation is carried out in the reverse order;
pay attention to the following points:
K -
Connect fuel pipes at the flange of the fuel
delivery unit:
♦ Blue return-flow pipe -1- at connection
marked with -R-.
♦ Black feed pipe -2- at connection marked
with -V-.
Connecting remote control
Special tools, testers and aids required
♦ Remote control V.A.G 1348/3A with adapter
cable V.A.G 1348/3-2
Procedure
-
Open cover of fuse box on the left-hand side
of the dash panel.
-
Remove fuse 28 at the fuse carrier (left row,
5th large fuse from top).
K -
Connect remote control V.A.G 1348/3A with
adapter cable V.A.G 1348/3-2 to the fuse
base of fuse 28 -arrow-.
-
Connect clamp to vehicle battery (+).
OCTAVIA
Edition 05.97
S00.5105.51.20