Servicing Processors (FRU)
The following section describes how to service processors. Processors are field-replaceable
units (FRUs). For more information about FRUs, see
and
"Field-Replaceable Units" on page
Ensure that all power is removed from the server before removing or installing a
Caution -
processor. You must disconnect the power cables from the system before performing these
procedures.
Processors must be removed and replaced only by authorized Oracle Service
Caution -
personnel.
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This sensitivity can cause the component to fail. To avoid damage, ensure that
you follow electrostatic discharge safety measures and antistatic practices. See
Discharge Safety" on page
Note -
On single-processor systems, processor socket 1 (P1) is shipped without a heatsink and
processor filler cover. To protect the delicate processor socket pins, do not remove the processor
cover that was installed on the motherboard.
This section covers the following topics:
"Identify and Remove a Faulty Processor" on page 144
■
"Install a Processor" on page 150
■
Related Information
"Servicing the DIMMs (CRU)" on page 117
■
22.
50.
"Illustrated Parts Breakdown" on page 20
Servicing Processors (FRU)
"Electrostatic
143