9.6.13 Crash Detection Duration (ID=1613)

Minimum
Maximum
value
value
0
600

9.6.14 Crash Detection Threshold (ID=1614)

Minimum
Maximum
value
value
16
1600

9.6.15 Towing Detection (ID=1291)

Towing detection can be set to: 0 – disabled (default), 1 – low priority event, 2 – high
priority event.
Minimum
Maximum
value
value
0
2

9.6.16 Towing Detection Activation Timeout (ID=1292)

Activation timeout is time after which FM turns ON Towing detection function if other
requirement is met (Ignition OFF state detected). It is measured in minutes.
Minimum
Maximum
value
value
0
2

9.6.17 Towing Detection Ignition check after event (ID=1295)

If ignition is OFF, event will be generated when TMO reached.
Minimum
Maximum
value
value
0
2
Recommende
Goes with (depends on)
d value
Crash Detection Enabled/disabled
-
Recommende
Goes with (depends on)
d value
Crash Detection Enabled/disabled
-
(ID=1612) Duration (ID=1613)
Recommende
Goes with (depends on)
d value
Activation Timeout (ID=1292)
Ignition check after event (ID=1295)
-
Recommende
Goes with (depends on)
d value
Towig detection enable/disable
Ignition check after event (ID=1295)
-
Recommende
Goes with (depends on)
d value
-
Towig detection enable/disable
Threshold (ID=1614)
parameters
(ID=1612)
Threshold (ID=1614)
parameters
parameters
Duration(ID1296)
Acceleration (ID=1297)
Angle(ID=1298)
parameters
(ID=1291)
Duration(ID1296)
Acceleration (ID=1297)
Angle(ID=1298)
parameters
Value
type
U8
Value
type
U8
Value
type
U8
Value
type
U8
Value
type
U8
71