Full Example Of Obd Parameter Configuration; Sms Event Configuration; I/O#1 Element Sms Event Configuration (Id=100) - Teltonika FM1000 ST User Manual

Table of Contents

Advertisement

9.9.3

Full example of OBD parameter configuration:

To configure Engine RPM PID 0C(Hex)=12(Dec) for 1 th slot, you must send SMS command:
[login] [pass] setparam 2150 12
Then other parameters can be configured similar to
– High level; 2153 – Low level; 2154 – Event type, 2155 – averaging length.
Example:
[login] [pass] setparam 2151 1

9.10 SMS event configuration

9.10.1 I/O#1 element SMS event configuration (ID=100)

Command sets SMS warning on I/O#1 element.
SMS Format: setparam X Y,W,Z;
X – ID;
Y – Enable/Disable (0/1);
W – Telephone number INDEX (See 9.4.15 SMS Event Predefined Numbers paragraph, ID
150 – INDEX 1; ID151 – INDEX 2, ...);
Z – SMS Text.
Example: "setparam 100 1,5,Digital Input 1 Event!"
Other I/O element SMS events can be configured in same logic. All I/O element SMS event
IDs are listed in the next table. OBD Iox (x – any number between 1 to 20) defines SMS event text
for configured OBD IO slot.
Element name (default
SMS Event Text)
Digital Input 1
PDOP
HDOP
Power voltage
Movement
Trip Distance
Actual operator Code
GPS speed
Operating Mode
GSM Signal
Deep Sleep
Cell ID
Area Code
Battery Voltage
I/O
parameters: 2151 – Priority; 2152
ID
100
101
102
103
104
105
106
107
108
109
110
111
112
113
81