Event Generating - Teltonika FM1000 ST User Manual

Table of Contents

Advertisement

the server by GPRS. Panic priority triggers same actions as high priority, but if GPRS fails, it sends
AVL packet using SMS mode if SMS data sending is enabled in SMS settings.
High and Low levels – define I/O value range. If I/O value enters or exits this range, FM1000
generates event. "Generate event" parameter defines when to generate event – when value
enters defined range, exits it or both.
Averaging constant – it is an I/O event delay parameter. In some applications there is no
need to generate events on every I/O range enter/exit immediately. Sometimes it is necessary to
wait some time interval before event generating. Averaging constant allows setting I/O event
delay (averaging). If I/O value is entering or leaving predefined range, it must have same value
for Averaging constant time. 1 Averaging constant value equals about 100 milliseconds.
Param = AvgConst(sek) * 10. For example, Value 3 = 300ms.
In Deep Sleep mode there is no Averaging.
Note: I/O element's "Movement" Averaging constant is interpreted as Start
Move Timeout in seconds (from 1 to 59).
Start Move Timeout – is a time interval required for accelerometer to be in the
moving state, to consider vehicle as moving.

5.12.1 Event Generating

Events happen when the value of enabled I/O intersects thresholds (enter, exit or on both)
predefined by High and Low level thresholds. Table below defines all available values of I/O
settings.
Setting
Priority
High level
Low level
Generate event
Average constant
Value
low, high
maximum threshold
minimum threshold
on interval enter, on interval exit, on both enter and exit
32
1 – 2
(4 Bytes)
Figure 31 Digital Input event generation example
43