1.9
Setting Recording Conditions (Recording mode,
recording interval, saving interval)
1.9.1
Setting the Type of Data to Record (Display or event data) and Recording
Conditions
Path
Description
1-94
Set the type of data to record (display or event data), the recording interval, and the interval
for saving measurement data files to an SD memory card.
GX/GP: MENU key > Browse tab > Setting > Setting menu Recording settings > Basic
settings
Web application: Config. tab > Recording settings > Recording basic settings
Hardware configurator: Recording settings > Recording basic settings
Recording mode
Setup Item
File type
1 Does not appear for the advanced security function (/AS option) or multi-batch function (/BT
option).
File type
Set the type of data to record.
Setup Item
Display
Display + Event
Event
Display Data, Trend Waveform
Setup Item
1
Saving interval
1 Does not appear when the file type is set to Event.
2 The minimum effective saving interval based on the trend interval of display data and the
number of recording channels.
Note
The maximum number of channels that the GX20/GP20 can record varies depending on the
trend interval and file type (for the GX20-2/GP20-2).
Trend Interval
(Unit: /div)
5s
10s
15s
30s or more
The GX10/GP10 can record up to 100 channels regardless of the trend interval or file type.
Selectable Range or Options
1
Display, Display + Event
, Event
Description
Records display data
Records display and event data
Records event data
Selectable Range or Options
10min, 20min, 30min, 1h, 2, h, 3h, 4h, 6h,
8h, 12h, 1day, 2day, 3day, 5day, 7day, 14day,
31day
GX20-1/GP20-1
Display
Display + Event
100ch
100ch
200ch
200ch
500ch
500ch
500ch
500ch
Default Value
GX10/GX20: Display
GP10/GP20: Event
Default Value
2
GX20-2/GP20-2
Display
Display + Event
200ch
100ch
500ch
200ch
1000ch
500ch
1000ch
1000ch