Chapter 1 Configuring the GX/GP
What Do You Want to Configure?
1. Measurement Source
Setting Measurement Conditions (Setting menu: Measurement settings)
2. Configuring Measurement Channels
Configuring Analog Input Channels (Setting menu: AI channel settings, AI (mA)
channel)
IM 04L51B01-01EN
You can assign DC voltages, thermocouples, RTDs, and on/off signals based on contacts
and voltages to channels to take measurements. The measurement section is modular, so it
can be expanded as necessary.
Input signals are sampled at the scan interval and converted to measured values through
A/D conversion.
Item
Setting the scan interval
Setting the operation mode of a module (AI module: 2ch mode/10ch mode, DI
module: normal/remote)
Setting the A/D integration time of an AI module (analog input module)
Setting how to detect over-range values
Setting the burnout criteria
You can set measurement conditions for each channel based on the input. You can calculate
the difference between two input values or convert input values to measurement values with
units that suit your purpose.
Alarms can be generated when measured data exceeds or goes below specified values.
Information that indicates alarm occurrence can be shown on the screen. Digital output
channels (DO channels) can be used to transmit relay contact signals.
You can change channel colors and assign tags to channels.
Source module: Analog input module (GX90XA)
Setting the Range
Item
Input range (type, range, span lower, span upper)
Performing input calculation (delta, linear scaling, square root)
Taking the moving average of input values (suppressing noise)
Setting the reference junction compensation mode (internal, external)
Setting burnout detection
Adding bias to input values
Setting Alarms
Item
Setting alarms (type, value, hysteresis, logging, output, alarm delay)
Setting the Display
Item
Setting channel tags (characters, No.)
Setting display colors
Dividing display areas to prevent waveform overlap (setting zones)
Setting the scale display position and divisions
Setting the base position and divisions of the bar graph display
Enabling the partial expanded display
Displaying the color scale band (band area (in, out), color)
Displaying alarm point marks (mark kind, alarm mark color)
Displaying on/off (1/0) signals with characters (when the range type is DI)
1
2
3
Reference
4
→page 1-90
→page 1-91
→page 1-92
→page 1-90
5
→page 1-93
App
Index
Reference
→page 1-13
Reference
→page 1-19
Reference
→page 1-23
→page 1-23
→page 1-85
→page 1-23
1-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartdac+ gp10Smartdac+ gx20Smartdac+ gp20

Table of Contents