Accessing The Cli; Web Browser Configuration; Preparing For Web Configuration - Advantech EKI-7428G Series User Manual

24g+4g combo port l2 managed switch
Table of Contents

Advertisement

such as Telnet, FTP, and SMTP. After each command is entered and processed, the switch
will issue a reply that consists of a numeric status code and a human-readable explanation
of the status.
The general format of commands is:
section parameter [value]
where:
section is used to group parameters.
parameter will specify the parameter within the section. For example, the network
section will have parameters for DHCP, IP address, subnet mask, and default gate-
way.
value is the new value of the parameter. If value is omitted, the current value is dis-
played.
Please note that new values will not take effect until explicitly committed.
Sections and parameter names are case sensitive (e.g., "Network" is not the same as "net-
work").
Any commands in the CLI Commands section of this chapter, with the exception of
the global commands, must be prefaced with the name of the section they are in.
For example, to change the IP address of the switch, you would type:
network address <newIP>

3.2.2 Accessing the CLI

To access the CLI interface, establish Ethernet or serial connectivity to the switch.
To connect by Ethernet, open a command prompt window and type:
telnet <switchip> (where <switchip> is the IP address of the switch)
At the login prompt, type "cli" for the username and "admin" for the password. The switch will
respond with "Managed switch configuration CLI ready".

3.3. Web Browser Configuration

The switch has an HTML based user interface embedded in the flash memory. The interface
offers an easy to use means to manage basic and advanced switch functions. The interface
allows for local or remote switch configuration anywhere on the network.
The interface is designed for use with [Internet Explorer (6.0), Chrome, Firefox].

3.3.1 Preparing for Web Configuration

The interface requires the installation and connection of the switch to the existing network. A
PC also connected to the network is required to connect to the switch and access the inter-
face through a web browser. The required networking information is provided as follows:
IP address: 192.168.1.1
Subnet mask: 255.255.255.0
C