Description of the device

4.7 Configuration License PLUG

NOTICE
Previous settings
If you reset, all the changes you have made will be overwritten by factory defaults.
NOTICE
Inadvertent reset
An inadvertent reset can cause disturbances and failures in a configured network with
further consequences.
4.7
Configuration License PLUG
The CLP (Configuration License PLUG) is used to transfer the configuration of the old
device to the new device when a device is replaced. The CLP is also referred to as PLUG
in the description.
The PLUG is available in the following variants:
• PLUG Configuration: The exchangeable storage medium only saves the configuration
data of the device.
• PLUG License: In addition to the configuration data, the exchangeable storage
medium contains a license with which special functions are enabled, e.g. iFeatures.
NOTICE
Loss of the degree of protection
When the cover is not mounted correctly, the device loses its degree of protection IP65
and is not water and dust proof.
Position
The CLP slot is at the bottom of the device enclosure under a cover, see Reset button
(Page 37).