Description
Use garp timer hold to set the GARP Hold timer for an Ethernet port, Layer-2 aggregate interface, or all
ports in a port group.
Use undo garp timer hold to restore the default of the GARP Hold timer. This may fail if the default is
beyond the valid value range for the Hold timer.
By default, the Hold timer is 10 centiseconds.
Related commands: display garp timer and garp timer join.
Examples
# Set the GARP Hold timer to 15 centiseconds, assuming that the Join timer is 30 centiseconds.
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] garp timer hold 15

garp timer join

Syntax
garp timer join timer-value
undo garp timer join
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default level
2: System level
Parameters
timer-value: Join timer (in centiseconds), which must be a multiple of 5 and range from twice the Hold
timer (inclusive) and half the Leave timer (inclusive).
Description
Use garp timer join to set the GARP Join timer for an Ethernet port, Layer-2 aggregate interface, or all
ports in a port group.
Use undo garp timer join to restore the default of the GARP Join timer. This may fail if the default is
beyond the valid value range for the Join timer.
By default, the Join timer is set to 20 centiseconds.
Related commands: display garp timer, garp timer hold, and garp timer leave.
Examples
# Set the GARP Join timer to 25 centiseconds, assuming that both the Hold timer and the Leave timer are
using the default.
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] garp timer join 25