Information List; Measurement - Siemens SIPROTEC 4 7SJ61 Manual

Multi-funktional protective relay with bay controller
Table of Contents

Advertisement

No.
Information
16001
ΣI^x A=
16002
ΣI^x B=
16003
ΣI^x C=
16006
Resid.Endu. A=
16007
Resid.Endu. B=
16008
Resid.Endu. C=
16011
mechan.TRIP A=
16012
mechan.TRIP B=
16013
mechan.TRIP C=
16014
ΣI^2t A=
16015
ΣI^2t B=
16016
ΣI^2t C=
2.17.2.6

Information List

No.
Information
10027
StartDuration1
10028
StartupCurrent1
10030
Nr.of Mot.Start
10031
Motor Run.Time
10032
Motor Stop.Time
10033
Perc.Run.Time
10037
StartDuration2
10038
StartupCurrent2
10040
StartDuration3
10041
StartupCurrent3
10043
StartDuration4
10044
StartupCurrent4
10046
StartDuration5
10047
StartupCurrent5

Measurement

2.17.3
A series of measured values and the values derived from them are constantly available for call up on site, or
for data transfer.
Applications
Information on the actual status of the system
Conversion of secondary values to primary values and percentages
Prerequisites
Except for secondary values, the device is able to indicate the primary values and percentages of the measured
values.
A precondition correct display of the primary and percentage values is the complete and correct entry of the
nominal values for the instrument transformers and the protected equipment as well as current and voltage
transformer ratios in the ground paths when configuring the device. The following table shows the formulas
which are the basis for the conversion of secondary values to primary values and percentages.
SIPROTEC 4, 7SJ61, Manual
C53000-G1140-C210-6, Edition 05.2016
Type of
Comments
Informa-
tion
VI
Sum Current Exponentiation Ph A to Ir^x
VI
Sum Current Exponentiation Ph B to Ir^x
VI
Sum Current Exponentiation Ph C to Ir^x
VI
Residual Endurance Phase A
VI
Residual Endurance Phase B
VI
Residual Endurance Phase C
VI
Number of mechanical Trips Phase A
VI
Number of mechanical Trips Phase B
VI
Number of mechanical Trips Phase C
VI
Sum Squared Current Integral Phase A
VI
Sum Squared Current Integral Phase B
VI
Sum Squared Current Integral Phase C
Type of
Comments
Informa-
tion
VI
Startup Duration 1
VI
Startup Current 1
VI
Total Number of Motor Starts
VI
Total Motor Running Time
VI
Total Motor Stopped Time
VI
Motor Percent Running Time
VI
Startup Duration 2
VI
Startup Current 2
VI
Startup Duration 3
VI
Startup Current 3
VI
Startup Duration 4
VI
Startup Current 4
VI
Startup Duration 5
VI
Startup Current 5
Functions