E E P R O M S E T T I N G S
Recommend to set ZON to the same value in all lifts belong to the group.
A lift shall zone to floor defined by LOB and ignore ZON, when working in simplex.
ZON EEPROM
00: 00000000 (No zoning). To disable zoning set "LOB" and "ZON" to "00".
80: 10000000 (Level 1)
40: 01000000 (Level 2)
20: 00100000 (Level 3)
10: 00010000 (Level 4)
08: 00001000 (Level 5)
04: 00000100 (Level 6)
ZTM - Zoning Time setup
This sets the amount of time prior to zoning to the "LOB" or "ZON" setting.
To disable zoning set "LOB" and "ZON" to "00".
ZTM EEPROM
The time is set in 10s increments.
06: 00001000 = 60s
0a: 00001010 = 100s, "1 minute 40 seconds"
12: 00010010 = 180s, "3 minutes"
#.L - Number of Lifts setup
This sets the number of lifts in the group.
All lifts within the group must be set to the same value.
#.L
EEPROM
01: 00000001 (1 Lift)
02: 00000010 (2 Lifts)
03: 00000011 (3 Lifts)
04: 00000100 (4 Lifts)
05: 00000101 (5 Lifts)
06: 00000110 (6 Lifts)
Set value to number of lifts. (01 to 06 valid values.)
Zone floor. (MASK) Zoning floors for other lifts.
Zoning time. (VALUE)
Number of Lifts (VALUE)