CFSS - Car Fire Service Start input...................................................... 28
DCBF - Door Close Button (Front doors) input................................... 28
DCBR - Door Close Button (Rear doors) input.................................... 28
DCF - Door Close (Front doors) relay output ...................................... 28
DCR - Door Close (Rear doors) relay output ....................................... 28
DDN - Direction Down output ............................................................... 28
DDO - Door Open Disable input / Toggle Switch................................. 28
DF - Down Fast relay output ................................................................. 29
DFCF - Door Fully Closed (Front doors) input.................................... 29
DFCR - Door Fully Closed (Rear doors) input..................................... 29
DFOF - Door Fully Open (Front doors) input...................................... 31
DFOR - Door Fully Open (Rear doors) input....................................... 31
DHC - Down Hall Call inputs/Darlington outputs ............................... 32
DN - Down Relay output ........................................................................ 33
DOBF - Door Open Button (Front doors) input................................... 33
DOBR - Door Open Button (Rear doors) input.................................... 33
DOF - Door Open (Front doors) relay output ...................................... 33
DOR - Door Open (Rear doors) relay output ....................................... 33
DS - Down Slow relay output................................................................. 33
DUP - Direction Up output .................................................................... 33
DZ - Door Zone input............................................................................. 33
DZ - Door Zone relay output ................................................................ 33
EP - Emergency Power input................................................................. 34
EQK - Earthquake Detection input...................................................... 34
HCB - Hall Call Bypass Input............................................................... 34
HFA - Hall Fire Alternate input............................................................ 34
HFL - Hall Fire Light output................................................................. 34
HFM Hall Fire Machine room/Hoist way input ................................... 34
HFR - Hall Fire Reset Input .................................................................. 34
HFS - Hall Fire Service input ................................................................ 35
HFV - Hall Fire Visual signal output .................................................... 35
HV2 - High Voltage input ...................................................................... 35
IDN - Inspection Down input................................................................. 35
IND - Independent Service input........................................................... 35
INSP - Inspection Control input............................................................ 35
IUP - Inspection Up input ...................................................................... 35
LEV - Leveling relay output .................................................................. 36
LR - Lock Relay input. ......................................................................... 36
LR - Lock Relay output......................................................................... 36
LRX - Aux LR input.............................................................................. 36
M3 - Door Locks input ........................................................................... 36
MSD - Magnetic Switch Down input .................................................... 36
MSU - Magnetic Switch Up input.......................................................... 36
NDGF - Nudging Buzzer output front doors ........................................ 37
NDGR - Nudging Buzzer output rear doors......................................... 37
NRF - Nudging output front doors ........................................................37
NRR - Nudging output rear doors .........................................................37
OS - Out of Service output .....................................................................37
PI - Position Indicator output ................................................................37
PRK - Parking function input ................................................................38
PRV - Proving Circuit input ..................................................................38
PULSE - Pulse Counting input..............................................................38
SAF - Safety Circuit input......................................................................38
Sin1 - BKSW - Brake Switch Input .......................................................39
SIn3 - HR Input......................................................................................39
SO2 - HR Output....................................................................................39
SP1 - Multi Purpose output 1.................................................................39
SP2 - Multi Purpose output 2.................................................................39
SP3 - Multi Purpose Output 3................................................................40
SP4 - Multi Purpose output 4.................................................................40
TSL - Top SLowing input ......................................................................40
UD - Up/Dn relay output ........................................................................40
UF - Up Fast relay output.......................................................................40
UHC - Up Hall Call inputs / outputs......................................................40
UP - Up relay output...............................................................................40
US - Up Slow relay output ......................................................................41
Section 5. Liquid Crystal Display.................................................................42
LCD Status Line...........................................................................................42
LCD Position & Direction ......................................................................42
LCD Modes..............................................................................................42
LCD Lift Status.......................................................................................43
LCD Door Modes ....................................................................................43
LCD Control Buttons .............................................................................44
LCD Display Options..............................................................................44
Section 6. Motion .........................................................................................46
Motion Control Outputs.........................................................................46
Drive settings and their output status....................................................46
Section 7: Faults - Fault finding.................................................................67
Upgrade Controller software. ................................................................67
Group/Duplex Faults ..............................................................................67
Leveling inhibit. LEV .............................................................................67
Run protection timer. RPT.....................................................................67
Lift won't re-level with doors open........................................................67
On board fuse blows ...............................................................................68
Testing 24Vdc..........................................................................................68
Doors do not open ...................................................................................68
Doors close on park.................................................................................68
Doors don't open at terminal floors.......................................................68