E E P R O M S E T T I N G S
RPT Run protection timer
Setting example:-RPT 01: 00000001
DRV Drive control type.
Setting example:-DRV 02: 00000010 (3010/2CH/S block)
ST2
Star Delta time.
Setting example:-ST2 08: 00001000
SDX Star Delta Exchange time. (VALUE)
Setting example:-SDX 01: 00000001 (= 100ms)
MSL Magnet slowing type.
Setting example:- MSL 00: 00000000 (MSU/MSD slowing)
RTM Extend run time. – If slowing is obtained less than this time, then add the value
of in XTM on before dropping high speed.
Setting example:-RTM 00: 00000000 (No extended run time.)
XTM Extend run time. – If a short floor determined by RTM then add this amount of
Setting example:-XTM 00: 00000000 (No extended run time.)
StF
Start Fast. -
Number of pulses it takes to reach fast speed.
StM
Start Medium.- Number of pulses it takes to reach medium speed.
SlF
Slow Fast. -
Number of pulses it takes to slow from fast speed.
SlM
Slow Medium.- Number of pulses it takes to slow from medium speed.
RLV Re-leveling. Turn re-leveling on/off.
Setting example:-RLV 00: 00000000
DLM Door limit mask.
Setting example:-DLM 00: 00000000 (Single doors.)
DLI
Door limit invert.
Setting example:-DLI 00: 00000000
NR
Nudging Relay for door nudging/Passing tone
Setting example:-NR 00: 00000000
ADO Advanced Door Opening.
Setting example:-ADO 00: 00000000 (Off )
DTCF Door time car call for front doors.
Setting example:-DTCF 32: 00110010 (= 5000ms, "5 seconds")
DTCR Door time car call for rear doors.
Setting example:-DTCR 32: 00110010 (= 5000ms, "5 seconds")
DTHF Door time hall call for front hall.
Setting example:-DTHF 32: 00110010
DTHR Door time hall call for rear hall.
Setting example:-DTHR 32: 00110010
DTL Door time lobby.
Setting example:-DTL 32: 00110010 (= 5000ms, "5 seconds")
ANS Anti Nuisance EDP. (VALUE)
Set to the number of times a car call is answered without EDP activation before calls are cancelled.
PRK Park/Zone with doors closed/open. Set to 00 – doors closed.
FS
Fire service type
Setting example:-FS 00: 00000000
DT
Door Time Close Setup. Door Time Canceling Function
Setting example:-DT 01: 00000001
BST
Brake Switch Time
Setting example:-BST 03: 00000011
(VALUE)
MSL 01: 00000001 (Pulse slowing)
Time on before dropping high speed.
RLV 01: 00000001 (Re-leveling on.)
DLM 01: 00000001 (Multi doors.)
DLM 02: 00000010 (Door cam.)
(MASK)
(VALUE)
(VALUE)
(VALUE)
(VALUE)
(VALUE)
FS 01: 00000001
(25s)
(= 800ms)
(No Re-level.)
(Limits not inverted.)
(MASK)
(Nudging off.)
(= 5000ms, "5 seconds")
(= 5000ms, "5 seconds")
(Australian fire service.)
(Code 17.1 U.S.A..)
(Door Timing Canceling Activated)
(3s)