M O T I O N
VF Drive Type 1
Keb, B&F, Zetadyn, C.T.
Setting "03"
Note:
1. To initiate a run, "PRV"
must be active prior to run.
"PRV" turns off during entire run and
becomes active to complete the run.
"PRV" is not required on inspection.
2. On inspection SP3 turns on for insp speed.
On inspection UF and DF turn off.
3. SP2 turns on for intermiediate speed (MSL=01 only)
4. US/ DS used for terminal speed check on lifts above 1m/s
5. SO1 turns on when performing a correction run. NOT used for INSP output
6. CFS and IND do not turn on OS output
2 Speed AC
Setting "04"
Note:
1.To initiate a run,
"PRV" must be active
prior to run.
"PRV" is not required
on inspection.
2. On inspection SP3 turns on for inspection speed.