Control Transformer Connections (Non-UPS)

Connect the AC input power to the control
transformer according to the following
procedure.
1. Ensure that the primary tap on the
control transformer matches the line
voltage and frequency connected to
the gate operator.
2. Measure the line voltage carefully to
distinguish between 208V and 230V
branch circuits.
NOTE: A label on the transformer top
identifies the various voltage taps available.
3. Use wire nuts or crimp-connectors to
connect the power input conductors
to the applicable taps on the Control
Transformer.

Gate Operator Connections (Modular Unit)

Control box with display
If you have the modular unit, additional conduit is needed to house the hydraulic hoses and electrical wiring.
You need a 2-inch (5 cm) diameter conduit for hydraulic hoses and a ¾-inch (19 mm) conduit for electrical
wiring. AC input power is connected to the hydraulic pump and electrical components enclosure
(HydraSupply).
A supplemental manual, provided with the product, describes the installation overview, wiring and conduit
considerations.
26
MX3630-01 Rev. J
High voltage electrical
power input wiring
SlideDriver/SlideDriver 50VF Series
Blue - 460 VAC
Orange - 240 VAC
Input taps
Red - 208 VAC
Black - Common
White - 120 VAC*
* Variable Frequency (VF) or 2 hp gate operators:
WARNING
Never connect to the white 120V wire. Make sure the
connection wires match the voltage found on the operator's nameplate.
All (Excluding SD50VF)
Electric motor
Hydraulic pump pack
Vehicle detector & control
signal input wiring
Control Transformer
.
.
.
.
.
VFD May 2017
SD50VF - series
Hydraulic motors,
Drive wheels,
Limit switches,
Toggle handle release