PAGE 36
Compressor failure and high tank level are fed to alarms 3 and 4. Since these are equipment problems, operations
technicians at 403-255-4437 and then 403-255-9545 are to be alerted. Follow the previous example to enter the
telephone numbers in Directory A and Directory B then set the alarms to use these two directories.
B1290:
Enter Program Code
YOU:
B1290:
Enter Configuration Code
YOU:
B1290:
Alarm One is Directory...
YOU:
B1290:
Alarm One is Directory A
YOU:
B1290:
Alarm Two is Directory...
YOU:
B1290:
Alarm Two is Directory A
YOU:
B1290:
Alarm Three is Directory A
YOU:
B1290:
Alarm Three is Directory B
B1290:
Alarm Four is Directory A
YOU:
B1290:
Alarm Four is Directory B
YOU:
The B1290 is now programmed to dial Directory A when alarms 1 or 2 occur, and Directory B when alarms 3 or 4
occur.
Example 4: Actuating Relays
In this example, when you receive the alarm "High Pressure" from the B1290, you would like to be able to operate a
bypass valve for up to ten minutes. The valve can be controlled by one of the relays on the B1290 using Relay On
and Relay Off codes.
B1290:
Enter Program Code
YOU:
B1290:
Enter Voice Code
YOU:
B1290:
Relay One is...
YOU:
B1290:
beep-beep
YOU:
Bypass Valve
B1290:
Relay One is Bypass Valve
YOU:
B1290:
Relay Two is...
YOU:
Select I/O Configuration
Select Using Directory
Select Directory A
Next
Select Directory A
Next
Select Directory B
Select Directory B
Quit
Select Voices
Select Relay Voices
Change
Next
Quit
PROGRAMMING EXAMPLES