SDI button menu (Option SDI only)
SDI OVERLAY BURNT-IN
Use this menu to overlay a timecode on the output test signal and set the display
position of the timecode. Use the up (▲) or down (▼) arrow button to change
TIMECODE submenu
the menu items. The following figure shows the SDI OVERLAY BURNT-IN
TIMECODE submenu.
Figure 31: SDI OVERLAY BURNT-IN TIMECODE submenu
Mode. Enables or disables the burnt-in timecode. Use the left (◄) or right (►)
arrow button to select between Enable, Small, and Large. Press the ENTER
button to confirm the selection.
X Position. Sets the horizontal position of the timecode. The position is set as a
percentage of active picture width. Use the left (◄) or right (►) arrow button to
change the position. You can set the value from -50.0% to 50.0% in 0.1% steps.
Y Position. Sets the vertical position of the timecode. The position is set as a
percentage of active picture height. Use the left (◄) or right (►) arrow button to
change the position. You can set the value from -50.0% to 50.0% in 0.1% steps.
SPG8000 Technical Reference