Burnt-In Timecode overlay
settings
SPG700 User Manual
Use these settings to overlay a timecode readout (HH:MM:SS;frames) on the
output test signal and set the size and position of the timecode readout. The
following figure shows the SDI Overlay Burnt-In Timecode submenu.

Figure 25: SDI Overlay Burnt-In Timecode settings

The following settings are available for the Burnt-In Timecode overlay:
BITC Mode. Use the drop-down list to disable the burnt-In Timecode or
select a Large or Small timecode.
X Position. Enter the horizontal position of the timecode. The position is set
as a percentage of active picture width. You can set the value from -50.0% to
50.0% in 0.1% steps.
Y Position. Enter the vertical position of the timecode. The position is set as
a percentage of active picture height. You can set the value from -50.0% to
50.0% in 0.1% steps.
Second Line Enable. Select the check box to enable a second line of
timecode readout (YY/MM/DD) on the output signal.
SDI menu (Option SDI only)