Tektronix SPG600 Quick Reference Manual
Tektronix SPG600 Quick Reference Manual

Tektronix SPG600 Quick Reference Manual

Sync pulse generator
Hide thumbs Also See for SPG600:

Advertisement

Quick Reference Manual
SPG600 & SPG300
Sync Pulse Generators
071-1341-02
This document supports firmware version 1.00
and above.
www.tektronix.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPG600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tektronix SPG600

  • Page 1 Quick Reference Manual SPG600 & SPG300 Sync Pulse Generators 071-1341-02 This document supports firmware version 1.00 and above. www.tektronix.com...
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material.
  • Page 3 Warranty 2 Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
  • Page 5: Table Of Contents

    ......... . . SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 6 ........Figure 29: Installation of slide-out track assemblies in rack (top view) SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 7: Related Manuals

    Preface This quick reference manual for the SPG600 and SPG300 Sync Pulse Generators provides the following information: H Identifies front-panel buttons and indicators H Identifies rear-panel connectors H Lists and describes menus H Rackmounting the instrument (SPG600 only) For more detailed information on how to use the sync pulse generator, refer to the SPG600 &...
  • Page 8 Tools Folder. This folder contains the Logo Generator application that provides the capability to convert a Windows bitmap file to a Logo file. For information on how to install and use Logo Generator, refer to the SPG600 & SPG300 Sync Pulse Generators User Manual.
  • Page 9: Figure 1: Spg600 Front Panel

    GENLOCK Button Use this button to access the Genlock menu. The Genlock menu lets you set genlock parameters such as genlock source and genlock timing. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 10 EXT.REF. This indicator lights when the sync pulse generator is locked to an external reference signal. A blinking indicator means that the sync pulse generator is using the external reference signal but is unable to lock to the signal. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 11: Figure 3: Spg600 Rear Panel (Option 0203)

    WARNING. To avoid dangerous electric shock, do not connect power to the instrument when the top cover is off. Dangerous potentials are present on the Power circuit board. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 12 Use the System menu to change the output configuration. CH5, CH6, CH7, and CH8 Analog black or analog test signal outputs (SPG600 Option 02 only). By default, the CH5, CH6, and CH7 connectors output black burst signals, and the CH8 connector outputs an analog test signal.
  • Page 13: Menus

    ) arrow button to scroll through the menu. Figure 5 shows the " Video menu diagram. Use the left ( ) or right ( ) arrow button to select functions or submenus in each Video menu. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 14: Figure 5: Video Menu Diagram

    CANCEL ENTER PARAMETER To SDI Parameters submenu SDI (STD) SDI (STD) (page 13) SDI (OPT) CANCEL 1 SPG600 Option 02 only 2 SPG600 Option 03 only Figure 5: Video menu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 15: Figure 6: Test Signal (Analog) Submenu Diagram

    Select a signal 100% Multiburst SWEEP Select a signal 100% Sweep PULSE BAR Select a signal 2T Pulse & Bar OTHER Select a signal FCC Composite Figure 6: Test signal (analog) submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 16: Figure 7: Test Signal (Sdi) Submenu Diagram

    2T Pulse & Bar MULTI BURST OTHER Select a signal Select a signal 60% Y Multiburst Chroma Freq. Resp. REC 801 Select a signal 100% Color Bars Figure 7: Test signal (SDI) submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 17: Figure 8: Timing (Analog) Submenu Diagram

    TIMING : VERTICAL Set the vertical timing in 1 line steps 0 Line (s) TIMING : HORIZONTAL Set the horizontal timing in 1 clock steps 0.00 μsec Figure 9: Timing (SDI) submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 18: Figure 10: Overlay Submenu Diagram

    : ANALOG (STD) To Logo submenu (page 11) Logo Logo To ID text submenu (page 12) ID Text CANCEL : ANALOG (STD) Fast HBlink OFF ↵ Figure 10: Overlay submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 19: Figure 11: Logo Submenu Diagram

    Figure 11: Logo submenu diagram You can create a logo file using the Logo Generator application. Refer to the SPG600 & SPG300 Sync Pulse Generators User Manual included on the product CD-ROM for detailed information for using Logo Generator. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 20: Figure 12: Id Text Submenu Diagram

    Y : 80.0%APH ENTER : ID TEXT : EDIT Edit text ENTER : ID TEXT : SAVE Save the text to the signal file ↵ Press ENTER Figure 12: ID text submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 21: Figure 13: Sdi Parameters Submenu

    : SDI (STD) COMPONENT Y,Cb HY, Cb, Cr ↵ Y,Cr : SDI (STD) PRECISION 10-bit H10-bit ↵ 8-bit : SDI (STD) EDH Disable HEnable ↵ Enable Figure 13: SDI parameters submenu SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 22: Figure 14: Audio Menu Diagram

    To Audio channel submenu Right Left (page 17) Both CANCEL Figure 14: Audio menu diagram NOTE. The ANALOG menu item is only available when you select Analog Audio in the CONFIGRATION: XLR OUTPUT menu. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 23: Figure 15: Aes/Ebu Submenu Diagram

    Emphasis: CCITT AES/EBU Resolution: 20 bits H Resolution: 20 bits ↵ Resolution: 24 bits AES/EBU Set the audio timing in 1 μs steps. Delay: 0.0 μsec Figure 15: AES/EBU submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 24: Figure 16: Embedded Submenu Diagram

    STD/BLK : GRP-1) Sync: w/o Frame No. H Sync: Frame ↵ Sync: Async STD/BLK : GRP-1 Resolution: 20 bits H Resolution: 20 bits ↵ Resolution: 24 bits Figure 16: Embedded submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 25: Figure 17: Audio Channel Submenu Diagram

    -48 dBu to 12 dBu (for analog audio) 1 Sec AES/EBU : CH-1 2 Sec H Audio Click: OFF ↵ 3 Sec 4 Sec * Not available for analog audio Figure 17: Audio channel submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 26: Figure 18: Genlock Menu Diagram

    PAL Burst CW 10 MHz ENTER GENLOCK TIMING To Genlock timing submenu (page 19) CANCEL LOCK LOSS ACTION Internal Mode H Internal Mode ↵ Stay Mode Figure 18: Genlock menu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 27: Figure 19: Genlock Timing Submenu Diagram

    TIMING : HORIZONTAL Set the horizontal timing in 1 clock steps 0.0000 μs TIMING : FINE Set the horizontal timing in 0.1 ns steps 0.0 nsec Figure 19: Genlock timing submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 28: Figure 20: System Menu Diagram

    SYSTEM PARAMETER To System information submenu (page 25) Information Information To System setup submenu (page 25) Setup CANCEL ENTER CONFIGURATION To Configuration submenu (page 26) CANCEL Figure 20: System menu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 29: Figure 21: Preset Submenu Diagram

    PRESET : RENAME Select a preset to Edit the preset name PRESET 1 rename CANCEL PRESE T : DELETE Select a preset to delete PRESET 1 Figure 21: Preset submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 30: Figure 22: Network Information Submenu Diagram

    Select Information in the NETWORK menu item : IP ADDRESS 123.123.123.123 : SUBNET MASK 255.254.253.252 : BROADCAST ADDR 111.255.255.255 : GATEWAY ADDR 000.000.000.000 : MAC ADDRESS 00-00-95-00-01-AE Figure 22: Network information submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 31: Figure 23: Network Setup Submenu Diagram

    Set the string H Disable ↵ public Enable Disable ENTER : SNMP MODE : SNMP GET COMMUNITY Enable Set the string H Disable ↵ private Read Only Figure 23: Network setup submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 32: Figure 24: Gpi Submenu Diagram

    Select GPI in the System menu : ALARM STATUS No Alarm : ALARM RESET ↵ Press ENTER : GPI ALARM OUTPUT Disable H Disable ↵ Enable Figure 24: GPI submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 33: Figure 25: System Information Submenu Diagram

    (Option 01). Figure 26 shows the System setup submenu diagram. Select Setup in the SYSTEM PARAMETER menu item ENTER : SETUP : OPTION KEY Enter the option key ABCDEFGHIJKLMNOPQRST Figure 26: System setup submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 34: Figure 27: Configuration Submenu Diagram

    H BLACK : 3 TEST: 4 ↵ BLACK : TEST : 3,4 SPG600 Option 03 only : XLR OUTPUT AES/EBU Audio H AES/EBU Audio ↵ Analog Audio Figure 27: Configuration submenu diagram SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 35: Rackmounting The Instrument (Spg600 Only)

    Rackmounting the Instrument (SPG600 Only) This section provides instructions for installing the SPG600 into a standard 19-inch equipment rack. NOTE. For information on how to install the SPG300 into a standard 19-inch equipment rack, refer to the Instructions included in each of the rackmounting kits.
  • Page 36: Installation Instructions

    5. Repeat steps 3 and 4 to assemble the left slide-out track assembly. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 37: Figure 28: Assembly Of Slide-Out Track Assemblies (Right Slide-Out Track)

    10-32 Panhead screws Front rack Flat bar nut Flat bar nut (use if front rail is not tapped) 10-32 Panhead screw Figure 28: Assembly of slide-out track assemblies (right slide-out track) SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 38: Figure 29: Installation Of Slide-Out Track Assemblies In Rack (Top View)

    Use flat head screws if the cabinet rails have countersunk mounting holes; otherwise use panhead screws Mounting Method A Mounting Method B Figure 29: Installation of slide-out track assemblies in rack (top view) SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 39 Repeat for the second mounting hole. Tighten both screws using 25 inch-lbs of torque. 10. Repeat step 9 to install the two screws in the left side of the front. SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...
  • Page 40 Rackmounting the Instrument (SPG600 Only) SPG600 & SPG300 Sync Pulse Generators Quick Reference Manual...

This manual is also suitable for:

Spg300

Table of Contents