SYSTEM button menu
Temperature Error. When enabled, sends an SNMP trap when a temperature error
in the instrument is detected. Use the left (◄) or right (►) arrow button to select
Enabled or Disabled. Press the ENTER button to confirm the selection.
You can use the DIAGNOSTICS submenu to view the current instrument
temperatures. (See page 157, DIAGNOSTICS submenu.)
GPS Signal Missing. When enabled, sends an SNMP trap when a loss of the
GPS input signal to the instrument is detected. Use the left (◄) or right (►)
arrow button to select Enabled or Disabled. Press the ENTER button to confirm
the selection.
Genlock Input Missing. When enabled, sends an SNMP trap when a loss of the
genlock reference input signal to the instrument is detected. Use the left (◄) or
right (►) arrow button to select Enabled or Disabled. Press the ENTER button
to confirm the selection.
Loss of Lock. When enabled, sends an SNMP trap when a loss of lock to the GPS
or genlock reference input signal to the instrument is detected. Use the left (◄)
or right (►) arrow button to select Enabled or Disabled. Press the ENTER
button to confirm the selection.
Near Loss of Lock. When enabled, sends an SNMP trap when a near loss of lock
to the GPS or genlock reference input signal to the instrument is detected. The
threshold for near loss of lock is approximately 2 × 10-6 from the ends of the tune
range. Use the left (◄) or right (►) arrow button to select Enabled or Disabled.
Press the ENTER button to confirm the selection.
VITC/LTC Missing. When enabled, sends an SNMP trap when a loss of the VITC
or LTC output signal from the instrument is detected. Use the left (◄) or right
(►) arrow button to select Enabled or Disabled. Press the ENTER button to
confirm the selection.
LTC Out of SMPTE. When enabled, sends an SNMP trap when the LTC input
signal to the instrument is detected to be noncompliant with the SMPTE standard.
Use the left (◄) or right (►) arrow button to select Enabled or Disabled. Press
the ENTER button to confirm the selection.
GPS FOM. When enabled, sends an SNMP trap when the quality of the GPS input
signal to the instrument is detected to be below the quality level limit configured
in the REF button menu. (See page 62, GPS SIGNAL WARNING.) Use the left
(◄) or right (►) arrow button to select Enabled or Disabled. Press the ENTER
button to confirm the selection.
Alarm Time. When enabled, sends an SNMP trap when the program time counter
matches the Alarm Time value configured in the TIME button menu. (See
page 175, ALARM TIME.) Use the left (◄) or right (►) arrow button to select
Enabled or Disabled. Press the ENTER button to confirm the selection.