Sdi Timecode Submenu - Tektronix SPG8000A User Manual

Master sync / clock reference generator technical reference
Hide thumbs Also See for SPG8000A:
Table of Contents

Advertisement

SDI Timecode Submenu

Source
Offset
ATC-LTC Enable
ATC-VITC Enable
30 DROP Frame Enable
SPG8000A User Manual
Use this submenu to set ancillary time code (ATC) parameters for the selected
output. Figure 30 shows the SDI Timecode submenu.
Figure 30: SDI Timecode submenu
Select the drop-down list and choose the time code source from these choices. The
default value is local (DST).
Local (DST): Uses the local time of day with Daylight Savings Time offset
as the time code.
Local (No DST): Uses the local time of day without Daylight Savings Time
offset as the time code.
UTC: Uses Coordinated Universal Time as the time code.
Program Time: Uses the program time counter as the time code.
Note: The Local (DST), Local (No DST) and UTC menu items are available only
when Option GPS is installed in the instrument.
Use this menu item to set a time code offset for the SDI outputs. This is an offset from
the selected time code source.
Note: The offset adjustment allows you to enter a time zone correction of up to
±23:59 hours. However, the ST309 standard only implements codes for time zones
in the range of -12 to +13 hours. Therefore, when you are using ST309 data as the
Time of Day source, it is recommended that the combined programmed offset from
time zone and DST be restricted to the range of -12 to +13 hours.
Select this check box to enable or disable the Ancillary Linear time code type of
ANC packets.
Select this check box to enable or disable the Ancillary Vertical Interval time code
type of ANC packets.
Select this check box to enable or disable the Drop Frame mode for the 30 frame
per second time code format. This menu item is available only when the frame or
field rate for the current format is 29.97 or 59.94.