memory-use-warn
Syntax
memory-use-warn rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
no memory-use-warn
Context
config>system>thresholds
Description
The memory thresholds are based on monitoring MemoryUsed object. This object contains the
amount of memory currently used by the system. The severity level is Alarm.
The absolute sample type method is used.
The no form of this command removes the configured compact flash threshold warning.
Parameters
rising-threshold threshold — The rising-threshold specifies a threshold for the sampled statistic.
falling-threshold threshold — The falling-threshold specifies a threshold for the sampled statistic.
interval seconds — The interval in seconds specifies the polling period over which the data is
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
7210 SAS D, E, K OS Basic System Configuration Guide
memory-use-alarm rising-threshold 50000000 falling-threshold 45999999 interval 500 rmon-
event-type both start-alarm either
When the current sampled value is greater than or equal to this threshold, and the value at the last
sampling interval was less than this threshold, a single threshold crossing event will be
generated. A single threshold crossing event will also be generated if the first sample taken is
greater than or equal to this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default
0
Values
-2147483648 — 2147483647
When the current sampled value is less than or equal to this threshold, and the value at the last
sampling interval was greater than this threshold, a single threshold crossing event will be
generated. A single threshold crossing event will also be generated if the first sample taken is
less than or equal to this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default
0
Values
-2147483648 — 2147483647
sampled and compared with the rising and falling thresholds.