cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period, in seconds, over which the data is sampled and
7210 SAS D, E, K OS Basic System Configuration Guide
less than or equal to the falling threshold value and startup-alarm is equal to falling or either, a
single falling threshold crossing event is generated.
Values
rising, falling, either
Default
either
Values
cf1:|cf2:|uf1: , cf1-A:
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated 'startup-alarm' is equal to 'rising' or 'either'.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the 'falling-
threshold' value.
Default
0
Values
-2147483648 — 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold value.
Default
0
Values
-2147483648 — 2147483647
compared with the rising and falling thresholds.
Values
1 — 2147483647