Alcatel-Lucent 7210 SAS-D Configuration Manual page 318

Service access switch
Hide thumbs Also See for 7210 SAS-D:
Table of Contents

Advertisement

System Alarm Commands
Description
This command configures memory usage, in kilobytes, for warning thresholds
Default
none
Parameters
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
interval seconds — Specifies the polling period over which the data is sampled and compared with
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created. If
Page 318
Guide
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default
0
Values
-2147483648 — 2147483647
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a falling threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold value.
Default
0
Values
-2147483648 — 2147483647
the rising and falling thresholds.
Values
1 — 2147483647
Values
log — In the case of log, an entry is made in the RMON-MIB log table for each
event occurrence. This does not create a TiMOS logger entry. The RMON-MIB log
table entries can be viewed using the show>system>thresholds CLI command.
trap — In the case of trap, a TiMOS logger event is generated. The TiMOS logger
utility then distributes the notification of this event to its configured log
destinations which may be CONSOLE, telnet session , memory log, cflash file,
syslog, or SNMP trap destinations logs.
both — In the case of both, both a entry in the RMON-MIB logTable and a TiMOS
logger event are generated.
none — In the case of none, no action is taken.
Default
both
the first sample is greater than or equal to the rising threshold value and startup-alarm is equal to
rising or either, then a single rising threshold crossing event is generated. If the first sample is
7210 SAS D, E, K OS Basic System Configuration

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-e7210 sas-k

Table of Contents