Alcatel-Lucent 7210 SAS-D Configuration Manual page 320

Service access switch
Hide thumbs Also See for 7210 SAS-D:
Table of Contents

Advertisement

System Alarm Commands
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
Configuration example:
cflash-cap-warn
Syntax
cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is warning. Both a rising and falling threshold can be specified. The no form of this
command removes the configured compact flash threshold warning.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
Page 320
Guide
Values
log — An entry is made in the RMON-MIB log table for each event occurrence.
This does not create a TiMOS logger entry. The RMON-MIB log table entries can
be viewed using the show>system>thresholds CLI command.
trap — A TiMOS logger event is generated. The TiMOS logger utility then
distributes the notification of this event to its configured log destinations which
may be CONSOLE, telnet session , memory log, cflash file, syslog, or SNMP trap
destinations logs.
both — Both a entry in the RMON-MIB logTable and a TiMOS logger event are
generated.
none — No action is taken.
Default
both
If the first sample is greater than or equal to the rising threshold value and startup-alarm is equal
to rising or either, then a single rising threshold crossing event is generated.
If the first sample is less than or equal to the falling threshold value and startup-alarm is equal to
falling or either, a single falling threshold crossing event is generated.
Default
either
Values
rising, falling, either
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900 interval 120
rmon-event-type both start-alarm rising.
Values
cf1:|cf2:|uf1:, cf1-A:
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
7210 SAS D, E, K OS Basic System Configuration

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas-e7210 sas-k

Table of Contents