T commands

TRIGger:FREQuency?

Group
Syntax
Returns
Examples

TRIGger:STATE?

Group
Syntax
Related commands
Returns
Examples
242
Returns the edge or pulse width trigger frequency. This is the same as the readout
in the lower right corner of the screen. Query only.
Trigger
TRIGger:FREQuency?
Edge or pulse width trigger frequency.
TRIGger:FREQuency? might return TRIGGER:FREQUENCY 1.0E3.
Returns the current state of the triggering system. Query only.
Trigger
TRIGger:STATE?
TRIGger:A:MODe
on page 230
ARMED indicates that the instrument is acquiring pretrigger information. All
triggers are ignored when TRIGger:STATE is ARMed.
AUTO indicates that the instrument is in the automatic mode and acquires data
even in the absence of a trigger.
READY indicates that all pretrigger information has been acquired and that the
instrument is ready to accept a trigger.
SAVE indicates that the instrument is in save mode and is not acquiring data.
TRIGGER indicates that the instrument triggered and is acquiring the post trigger
information.
TRIGGER:STATE? might return :TRIGGER:STATE ARMED indicating that
the pretrigger data is being acquired.