Wfmoutpre:xincr; Wfmoutpre:xunit - Tektronix TBS2000 Series Programmer's Manual

Digital oscilloscope
Hide thumbs Also See for TBS2000 Series:
Table of Contents

Advertisement

WFMOutpre:XINcr?

Group
Syntax
Related commands

WFMOutpre:XUNit?

Group
Syntax
TBS2000 Series Programmer
Returns the horizontal point spacing in units of WFMOutpre:XUNit for the
waveform specified by the DATa:SOUrce command. This value corresponds to
the sampling interval. The query command will time out and an error will be
generated if the waveform specified by DATa:SOUrce is not turned on. Query
only.
Waveform
WFMOutpre:XINcr?
DATa:SOUrce
on page 91,
Examples
WFMOUTPRE:XINCR? might return :WFMOUTPRE:XINCR 10.0000E-6
indicating that the horizontal sampling interval is 10 μs/point.
Returns the horizontal units for the waveform specified by the DATa:SOUrce
command. The query command will time out and an error will be generated if the
waveform specified by DATa:SOUrce is not turned on. Query only.
Waveform
WFMOutpre:XUNit?
WFMOutpre:XUNit?
on page 263
W commands
263