C commands
CH<x>:PRObe:FORCEDRange
Group
Syntax
Arguments
Returns
68
Sets or returns the range of a TekVPI probe attached to the channel specified by
<x>, where x is the channel number.
NOTE. This command returns 0.0 for probes that do not forced range.
Vertical
CH<x>:PRObe:FORCEDRange <NR3>
CH<x>:PRObe:FORCEDRange?
<NR3> specifies the range, which is probe specific.
This command returns 0.0 for probes that do no support forced range.
Examples
CH1:PRObe:FORCEDRange 0.3 set the range of the probe on channel 1 to 0.3.
CH1:PRObe:FORCEDRange? might return CH1:PRObe:FORCEDRange
0.0 indicating that the probe attached to channel 1 does not support forced range.