Calibrating The Sensors - DeDietrich AWHP 6 MR Installation And Service Manual

Air / water heat pump
Hide thumbs Also See for AWHP 6 MR:
Table of Contents

Advertisement

AWHP MIT-IN iSystem
0
2
4
6
8
E
1
2
1
D
2
bar
#
F

% $
AUTO
J
I
STD
User level - Menu #SETTING
Parameter
Adjustment range Description
15 to 30 °C
SUM/WIN
NO
CALIBR. OUT
CALIBR. ROOM A
(1)
-5.0 to +5.0 °C
OFFSET ROOM A
(2)
0.5 to 20 °C
ANTIFR. ROOM A
CALIBR. ROOM B
(1) (3)
-5.0 to +5.0 °C
OFFSET ROOM B
(2) (3)
(3)
0.5 to 20 °C
ANTIFR. ROOM B
CALIBR. ROOM C
(1) (3)
-5.0 to +5.0 °C
OFFSET ROOM C
(2) (3)
0.5 to 20 °C
(3)
ANTIFR. ROOM C
(1) The parameter is only displayed if a room sensor is connected to the circuit concerned
(2) The parameter is only displayed if no room sensor is connected to the circuit concerned or the sensor has no influence
(3) The parameter is only displayed if the circuit concerned is actually connected
24/09/2012 - 300027606-001-01
10
12
14
16
18
20
22
24
SUNDAY 11:45
!
:
<
C002219-D-04
Used to set the outside temperature above
which heating will be shut down.
The heating pumps are shut down.
4
The heat pump only starts up for
4
domestic hot water needs.
In this case the letter E and symbol p
4
are displayed.
Heating is never shut down automatically
Outside sensor calibration: Used to correct
the outside temperature
Calibration of the room sensor on circuit A
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room offset on circuit A: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room temperature antifreeze activation on
circuit A
Calibration of the room sensor on circuit B
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room offset on circuit B: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room temperature at which the antifreeze
mode is activated on circuit B
Calibration of the room sensor on circuit C
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room offset on circuit C: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
Room temperature antifreeze activation on
circuit C
5.6.2.

Calibrating the sensors

1. To access user level: Press the > key.
2. Select the menu #SETTING.
Turn the rotary button to scroll through the menus or
4
modify a value.
Press the rotary button to access the selected menu
4
or confirm a value modification.
¼ For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 75
3. Set the following parameters:
5. Commissioning
Factory setting
Customer
setting
22 °C
Outside
temperature
Room temperature
of circuit A
0.0
6 °C
Room temperature
of circuit B
0.0
6 °C
Room temperature
of circuit C
0.0
6 °C
90