DeDietrich AWHP 6 MR Installation And Service Manual page 95

Air / water heat pump
Hide thumbs Also See for AWHP 6 MR:
Table of Contents

Advertisement

AWHP MIT-IN iSystem
Installer level - Menu #SECONDARY INSTAL.P
Parameter
Adjustment range
0 (10 hours) to 10
(1)
BUILD. INERTIA
(50 hours)
0 to 4
(2)
CIRC.CURVE A
0 to 10
(2)
ROOM INFL. A
OFF, 7 to 22 °C
(3)
MINI COOLING A
(2)
0 to 4
CIRC.CURVE B
0 to 10
(2)
ROOM INFL. B
OFF, 7 to 22 °C
(3)
MINI COOLING B
0 to 4
(2)
CIRC.CURVE C
0 to 10
(2)
ROOM INFL. C
OFF, 7 to 22 °C
(3)
MINI COOLING C
(1)
4 to 16 K
BAND WIDTH
0 to 16 K
BOIL/3WV SHIFT
SCREED DRYING
NO, B, C, B+C
20 to 50 °C
START DRYING
(4)
TEMP
20 to 50 °C
STOP DRYING TEMP
(4)
(4)
0 to 99
NB DAYS DRYING
(1) The menu is displayed only if the INSTALLATION parameter is set to EXTENDED.
(2) The parameter can be set to the heating curve by pressing key f.
(3) The parameter is only displayed if the circuit is configured to 3WV or FAN CONVECTOR and the COOLING parameter is other than OFF.
(4) The parameter is only displayed if SCREED DRYING is other than OFF.
(5) The parameter is only displayed if the IN 0-10V parameter is not set to NO.
(6) The parameter is only displayed if a room sensor is connected.
24/09/2012 - 300027606-001-01
Description
Characterisation of building's inertia:
0 for a building with low thermal inertia.
3 for a building with normal thermal
inertia.
10 for a building with high thermal
inertia.
Modification of the factory setting is
only useful in exceptional cases.
Heating curve of the circuit A
¼ "CIRC. CURVE ...", page
96
Influence of room sensor A
¼ "ROOM S.INFL", page
97
Flow set point for the circuit
Heating curve of the circuit B
¼ "CIRC. CURVE ...", page
96
Influence of room sensor B
¼ "ROOM S.INFL", page
97
Flow set point for the circuit
Heating curve of the circuit C
¼ "CIRC. CURVE ...", page
96
Influence of room sensor C
¼ "ROOM S.INFL", page
97
Flow set point for the circuit
Control unit bandwidth for the 3-way
valves.
Option of increasing the bandwidth if
the valves are rapid or of reducing it if
they are slow.
Minimum temperature divergence
between the heat pump and the valves
Drying the floor
¼ "SCREED DRYING", page
96
Screed drying start temperature
Screed drying stop temperature
5. Commissioning
Factory setting Customer
setting
3 (22 hours)
1.5
3
10°C
0.7
3
10°C
0.7
3
10°C
12 K
4 K
NO
20 °C
20 °C
0
94