DeDietrich AWHP 6 MR Installation And Service Manual page 58

Air / water heat pump
Hide thumbs Also See for AWHP 6 MR:
Table of Contents

Advertisement

4. Installation
Settings to be made for this type of installation
Parameters
Access
Installer level
INSTALLATION
#SYSTEM menu
Installer level
(1)
O.PUMP A
#SYSTEM menu
(1)
Installer level
CIRC. A:
#SYSTEM menu
(1) The parameter is only displayed if INSTALLATION parameter is set to EXTENDED
57
Connect the outside temperature sensor.
E
Connect the 3-way valve motor (circuit B) and the circuit
R
B flow sensor.
Connect the heating pump (Circuit B).
T
Connect a safety thermostat if the heating circuit is for
Y
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Connect the DHW sensor (Package AD212).
U
Connect the DHW tank anode.
I
CAUTION
4
4
Not used: Do not connect anything to the terminal block.
O
Connect the motor on the DHW reversal valve.
P
Connect the domestic hot water looping pump to the
a
MA outlet.
Connect the BUS cable between the outside module and
z
the terminal block on the inside module.
See chapter: ¼ "Connecting the communication
cable between the inside and outside modules", page
45.
Connect the relay command on the tank heating resistor
e
to the ELEC ECS terminal block.
Connect the condensation detector (Option).
r
The condensation detector shuts down cooling if
there is a risk of condensation.
CAUTION
We strongly recommend installing the cold
mode insulation kit (package HK24) to prevent
any risk of condensation in the inside module.
Settings to be made See chapter
EXTENDED
DHW LOOP
FAN CONVECTOR
AWHP MIT-IN iSystem
If the tank is fitted with a Titan Active
System® impressed current anode,
connect the anode to the inlet (+ TA on the
anode, - on the tank).
If the tank is not fitted with an impressed
current anode, put the simulation
connector in place (delivered with the DHW
sensor - package AD212).
¼ "Displaying the parameters in
extended mode", page 78
¼ "Setting the parameters specific to
the installation", page 78
¼ "Setting the parameters specific to
the installation", page 78
24/09/2012 - 300027606-001-01