4. Installation
PCU
1
2
49
Type
Three-phase /E2
4.11.11.
WARNING
Respect the polaritie of the terminals: Live (P), neutral
(N), and earth (*).
A
Z
M002423-B
BACKUP TYPE
Back-up
setting
Stage1
Stage2
Stage1 + 2 12 kW
Stage1
Stage2
Stage1 + 2 12 kW
Stage1
Stage2
Stage1 + 2 8 kW
Stage1
/E1
Connecting the hydraulic auxilary on the
inside module (MIT-IN/H only)
Back-up pump
Burner (Volt free contact)
AWHP MIT-IN iSystem
Output Bridge
4 kW
between C3 and
C2
8 kW
8 kW
between C2 and
C1
4 kW
4 kW
Remove bridge
4 kW
8 kW
between C2 and
C1
4 kW
Remove bridge
24/09/2012 - 300027606-001-01